v0.17.0 — 2026-09-13

The stable cut of the 0.17.0 line, consolidating its whole beta cycle. The headline: Navigator 1.0/1.7 heat pumps are supported — automatically detected, served their own register map from the official 1.x table, with writable PV-supplement registers on updated firmware. The rest is the September code audit: eight bugs fixed (a poll outliving its config entry, a failed setup leaving live entities behind, Fahrenheit room sensors written as Celsius, sentinel readings on thermostat cards, and more), hardening of the web supplement and the DHW boost, and the automation that keeps the dependency pins current on its own. Runtime: idm-heatpump-api 2.1.1, modbus-connection 4.11.1. The full, authoritative changelog is in docs/CHANGELOG.md; from this release on it is kept version-to-version (beta sections are folded into the stable section at the cut).

v0.17.0-beta.1 — 2026-09-09

First candidate of the 0.17.0 line, carrying the result of the code audit in docs/dev/code-audit-2026-09.md. Eight bugs are fixed — among them a poll that outlived its config entry, a failed setup that left live entities behind, a second heat pump behind one Modbus gateway that could no longer be added, forwarded room temperatures that were not converted to degrees Celsius, and sentinel readings that reached a temperature state — together with six robustness items and three performance items. Both runtime pins move forward (modbus-connection 4.11.1, idm-heatpump-api 2.0.1). No register map and no entity identifier changed.

It is a beta: the audit touched model detection, setup and teardown, write-enabled entities and services, and a runtime dependency change restarts the soak clock. Verification progress is tracked in docs/release-evidence/0.17.0-beta.1.md.

v0.16.1 — 2026-08-28

Patch on 0.16.0, from a live Home Assistant log. With the optional web supplement pointed at an IP address, the integration closed a Home Assistant aiohttp session instead of detaching it — Home Assistant wraps close() on every session its helpers hand out, because the connector below it is shared with every other integration. The session is now released with detach(), and created with auto_cleanup=False so a web client rebuilt after a failed poll does not leave the previous session pinned until Home Assistant stops.

A hostname was never affected; it borrows the shared session, which the integration never released. Polling, entity state, writes, the KNX bridge and the Modbus path are unchanged, as are the runtime pins.

v0.16.0 — 2026-08-28

First stable release of the 0.16.0 line. It closes 0.16.0-beta.1 through 0.16.0-rc.6 with no code change since RC6.

The headline is the experimental KNX bridge. The integration serves the 654 IDM KNX communication objects itself — same object numbers, datapoint types and read/write directions as IDM's ETS example project — so the Weinzierl KNX IP BAOS 774 gateway module is no longer needed. It is opt-in, off by default, and drives the Home Assistant knx integration, which is where tunnelling, routing and KNX Secure stay. One base group address configures all objects; idm_heatpump.export_knx_group_addresses and scripts/generate_knx_group_addresses.py produce the ETS import. Physical-bus interoperability is still unverified, which is why the feature is labelled experimental.

Breaking: pymodbus is gone. The integration requires idm-heatpump-api[web]==2.0.0 and speaks Modbus TCP through modbus-connection==4.10.0 / tmodbus[async-serial]==0.6.1 only. 0.15.1 is the last line with pymodbus. Nothing on the wire changes — register addresses, entity IDs, unique IDs and the write path are identical, so entities, history, automations and dashboards survive the update.

Also in the line: every entity name resolves through a Home Assistant translation key, so an English installation finally shows English names; heating circuits, optional modules and rooms became child devices on Home Assistant 2026.9 without losing a device ID; strict mypy runs with nothing disabled; and the test suite is gated at 95 % coverage with config_flow.py at 100 %.

See KNX Bridge.

v0.16.0-rc.6 — 2026-08-27

The KNX bridge now recovers when IDM starts before Home Assistant's KNX runtime has finished loading. Group-address event registration is retried every five seconds, and partial success is retained so only missing DPT batches are tried again. No manual IDM integration reload is required.

RC5's latest-value command queue and all write protections are unchanged. The EEPROM-sensitive classification and configurable 60-second default remain as before; registration recovery sends no bus telegram and writes no controller register by itself.

v0.16.0-rc.5 — 2026-08-27

Incoming commands for the experimental KNX bridge now use a latest-value-wins queue. Rapid intermediate setpoints are coalesced for one second, and a valid command that encounters the general cooldown or EEPROM protection remains queued until the guard expires instead of being lost. The EEPROM-sensitive register classification and the configurable 60-second default are unchanged.

The options text now distinguishes the live evidence precisely: setup and reload were verified with an active Home Assistant KNX interface in safe receive-only mode, while physical group-address telegram interoperability and bus load remain open because no IDM group addresses were imported into ETS.

See KNX Bridge.

v0.16.0-rc.4 — 2026-08-27

Entity names are translated. Until now only a handful of control entities had translations; every other entity — the Modbus registers, the calculated and operating-analysis sensors, the technician codes and the local web supplement values — carried a hardcoded German name in every language. All of them now resolve through a Home Assistant translation key, so an English installation shows English names and a German one shows the names it always had. Entity IDs and unique IDs are unchanged.

The rest of the candidate is quality-scale work with no user-visible effect: the config flow reached 100 % test coverage and the suite 95 %, both enforced in CI; the optional web clients use Home Assistant's own aiohttp session; and strict typing lost its seven disabled error codes.

See Entities.

v0.16.0-rc.3 — 2026-08-27

Optional, experimental KNX bridge: the integration can serve the IDM KNX communication objects — same object numbers, datapoint types and read/write directions as IDM's ETS example project — through the Home Assistant knx integration, so the Weinzierl KNX IP BAOS 774 gateway module is no longer needed. KNX Secure, tunnelling and routing come from the knx integration. One base group address configures all 654 objects, and idm_heatpump.export_knx_group_addresses returns the table for ETS.

Experimental: unit-tested, but never yet exercised against a real KNX bus.

See KNX Bridge.

v0.15.0 — 2026-08-22

Stable release closing the 0.15.0-beta.1..beta.3 cycle. No breaking changes: unique IDs, entity IDs, register addresses and write paths are unchanged, and an existing config entry keeps polling exactly as before.

Changed

  • Transport off the alpha pin: modbus-connection==4.8.1 and tmodbus[async-serial]==0.5.1 (previously 4.0.0a3 / 0.5.0), with a typed error hierarchy and ModbusDesyncError for gateways serving several clients.

Added

  • Web room temperature sensors for all heating circuits A–G: B61–B67 (room_temperature_HK_A..G), verified live on Navigator 10 ALM 6-15.
  • Connection pacing options under "Advanced Modbus settings": pause between requests (0–0.5 s) and pause after connect (0–5 s), both 0 by default.
  • Automated dependency pin freshness checking and an English documentation contract, both enforced in CI.

Fixed

  • Inverted NC digital inputs in the web supplement: ew_evu_lock_contact, dewpoint_humidity_alarm and failure_eheating now report off in normal operation and on on alarm, lock or fault.
  • Orphaned deprecated sensor entities: stale sensor.*_web entries left over from the binary_sensor migration are cleaned from the entity registry at startup.

Release gate note: this stable tag was cut without the seven-day soak and without a signed stable-candidate smoke test — a deliberate maintainer decision, recorded in docs/release-evidence/0.15.0.md and on Stability and Release Readiness.

v0.15.0-beta.3 — 2026-08-22

Beta candidate 3: adds room temperature sensors for all heating circuits (A–G) in the optional Navigator web supplement, bumps idm-heatpump-api to 1.0.2.

Added

  • Web room temperature sensors for all heating circuits A–G: Support for B61–B67 (room_temperature_HK_A..G), verified live on Navigator 10 ALM 6-15 (B64 = 21.8 °C).
  • idm-heatpump-api[web]: Bumped to 1.0.2.

v0.15.0-beta.2 — 2026-08-22

Beta candidate 2: fixes inverted state on normally closed (NC) digital inputs in the Navigator web supplement, automatically cleans up orphaned legacy sensor entities in Home Assistant's entity registry, and adds automated dependency pin freshness checking.

Fixed

  • Inverted NC digital inputs in Web supplement: ew_evu_lock_contact, dewpoint_humidity_alarm, and failure_eheating are Normally Closed contacts and now correctly report off in normal operation and on on alarm/lock.
  • Orphaned deprecated sensor entities cleanup: Stale sensor.*_web entities migrated to binary_sensor are automatically cleaned from Home Assistant's entity registry at startup.
  • Dependency pin updater platform support: Normalized paths to POSIX format.

Added

  • English documentation contract: Enforced by tests.
  • Automated dependency freshness checking: Daily PyPI pin verification.

v0.15.0-beta.1 — 2026-08-19

Beta candidate: the transport pin moves off the modbus-connection==4.0.0a3 alpha onto 4.8.1, plus two new pacing options that are off by default. Because this changes the runtime dependency of the direct Modbus socket, it ships through the pre-release channel — the soak clock for a stable tag restarts with this candidate. No breaking changes; unique IDs, entity IDs, register addresses and write paths are unchanged, and an existing config entry polls exactly as before without any action.

Changed

  • Transport pinned to modbus-connection==4.8.1 and tmodbus[async-serial]==0.5.1 (previously 4.0.0a3 / 0.5.0). The newer library adds a typed error hierarchy, connection-wide pacing, and — since 4.8.0 — ModbusDesyncError: when a peer answers a different request than the one sent (typical for a gateway serving several Modbus clients at once), the backend drops the link instead of decoding the foreign reply. The async-serial extra is not optional even though this integration is TCP-only: since modbus-connection 4.7.0 the backend module imports serialx at module level.
  • Transport error translation now uses the typed exceptions instead of comparing exception_code numbers. The contract is unchanged: code 2 stays IllegalAddressError (coordinator bisect), codes 5/6/10/11 stay on the retry-in-place path, and the exception_code=<N> marker the coordinator matches on is still rendered as a number.

Added

  • Two options under "Advanced Modbus settings", both 0 by default: pause between requests (0–0.5 s, minimum gap from the end of one request to the start of the next) and pause after connect (0–5 s, once per connect and reconnect). Raise them for controllers or gateways that answer "device busy", drop requests, or time out under a dense request stream. The guided setup profiles set the request pause along: "unreliable network" 0.05 s, "multiple clients" 0.1 s.

v0.14.1 — 2026-08-18

Patch release: three bugs around the lifecycle of optional heating circuits. No breaking changes; unique IDs, register addresses and write paths are unchanged.

Fixed

  • Sensors of a circuit enabled later never appeared. Entities are only built while the config entry loads. If the controller still reported the -1.0 sentinel in that one poll, the "hide unused sensors" filter dropped the circuit's read-only registers — so the circuit got its controls but neither flow, room nor setpoint temperature, until some later reload happened to catch better values. A configured circuit is now exempt from that filter, the same way writable controls already were. Availability still follows the live value.
  • Flow deviation showed the flow temperature while idle. A circuit that asks for nothing reports setpoint 0.0. That is a normal operating state, not a declared sentinel, so the sensor computed flow - 0 and published the measured flow temperature as a 26 K deviation. It is now suppressed (state unknown) while the circuit requests nothing, like the COP sensor at standstill.
  • "Unnamed device" in the device list. Sub-devices are created before the platforms so via_device links resolve regardless of platform order; their name only arrives with the first entity. A sub-device that never received one stayed in the list as an unnamed, empty entry. Those are now detached when the config entry loads. A sub-device whose entities the user merely disabled is kept.
  • Orphaned entities of deselected circuits. Unchecking a circuit left its entities in the registry as permanently unavailable. They are now removed when the config entry loads, narrowly scoped to register-backed entities of this entry whose register points at an unconfigured circuit. Re-enabling the circuit recreates them under unchanged unique IDs.

v0.14.0 — 2026-08-18

Minor release: one usability fix on the heating curve, the circuit design parameters become expert entities, plus a per-circuit dashboard example and a contract test that catches the root cause of the 0.13.0 bug in CI. Config entries, entity IDs, unique IDs, register addresses and write paths are unchanged, and the tested dependency pairing is identical to 0.13.0.

Fixed

  • Heating curve step size. hc_{a..g}_heating_curve is a FLOAT register and therefore inherited the default step of 0.5, even though its range is 0.1–3.5. Common settings such as 0.3 or 0.4 fell between two steps and could not be entered. The step is now 0.1; the range still comes from idm-heatpump-api.

Changed

  • Heating-curve parameters are expert entities. hc_{x}_heating_curve, hc_{x}_parallel_shift, hc_{x}_setpoint_flow_constant and hc_{x}_setpoint_flow_cooling are created disabled on new installations, like power_limit_hp already was. They define the design of the whole heating system and write to EEPROM registers. Existing installations are unaffected — entity_registry_enabled_default only applies when an entity is first created.

Added

  • Per-circuit dashboard example (docs/examples/dashboard-idm-heating-circuit.yaml). Home Assistant sorts a device page alphabetically and mixes comfort setpoints with design parameters; the example keeps them in separate sections and adds a history graph of measured flow, requested flow, room and outdoor temperature.
  • Contract test for the web value keys (tests/test_cross_repo_contract.py). It compares the value names idm-heatpump-api can deliver against the keys the integration turns into entities and fails as soon as the API provides a value the integration would silently discard — the root cause of the circuit B–G bug in 0.13.0.

v0.13.0 — 2026-08-18

Minor release with one fix that makes new entities appear on systems with more than one heating circuit, plus German names for the optional circuits. Fully backward compatible: config entries, entity IDs, unique IDs, register addresses and write paths are unchanged, and the tested dependency pairing is identical to 0.12.0.

Fixed

  • Web entities for every heating circuit, not just circuit A. The Navigator web values for the circuit pump (M31–M37), mixer (M41–M47) and flow temperature (B51–B57) are provided by idm-heatpump-api for circuits A–G, but the integration only picked up the circuit-A keys from a static allowlist. A circuit enabled later through the options flow therefore never received its (Web) entities — the values arrived and were discarded. Web entities are now created per configured heating circuit, so they appear on the reload that follows a later activation.
  • German names for heating circuits B–G. The name table only contained hc_a_* entries, so every optional circuit fell back to the English default (Hc D Cooling Limit instead of Kühlgrenze HK D). Names for B–G are now derived from the circuit-A table. Entity IDs and unique IDs are unchanged; only the displayed name differs.

v0.12.0 — 2026-08-17

Minor release with two new features and one polling fix. Fully backward compatible: config entries, entity IDs, unique IDs, register addresses and write paths are unchanged, and the tested dependency pairing is identical to 0.11.1.

Added

  • Flow deviation per heating circuit (calculated_hc_{a..g}_flow_deviation): the measured flow temperature of a circuit minus the flow setpoint the controller requests for that same circuit. Positive means overshoot, negative means the circuit does not reach its setpoint — the key figure when tuning a heating curve. Nothing is estimated; both operands are decoded registers of one circuit. Idle (0.0) and unconfigured (-1.0) circuits report unavailable instead of a meaningless deviation. With device hierarchy enabled the sensor sits on its heating-circuit device.
  • Self-diagnosis for a scan interval that is too short: when polling takes at least 80% of its own interval for several cycles in a row, a repair issue explains the situation and names the three effective remedies. This saturation is what turns into timeouts, especially when a second Modbus client shares the controller.

Fixed

  • Calculated sensors could lose their source registers under entity-aware polling — calculated_cop was missing from the hand-maintained dependency list, so disabling the two power sensors made the COP sensor permanently unavailable. Dependencies are now derived from the sensor definitions.

See docs/CHANGELOG.md for the full entry including test and CI changes.

v0.11.1 — 2026-08-15

Patch release fixing #192: a runtime model correction from the web supplement (e.g. Navigator 2.0 → Navigator 10 based on a NAV10 firmware-string match) updated the coordinator's live state, but Home Assistant's Device Registry — populated once at entity-setup time — never received the correction, since that detection key is deliberately excluded from the reload fingerprint to avoid tearing down active connections. The device page kept showing the original model while diagnostics already showed the corrected one. The coordinator now pushes a changed model/firmware/serial number directly into the Device Registry whenever a correction actually changes one of them.

v0.11.0 — 2026-08-15

First stable release of the 0.11.x line, after eight betas (0.11.0-beta.1 – 0.11.0-beta.8). Fully backward compatible: existing config entries, entity IDs, register addresses and write paths are unchanged. See docs/CHANGELOG.md for the full consolidated changelog.

Added

  • Direct Modbus TCP socket now runs through modbus-connection==4.0.0a3 with the tmodbus==0.5.0 backend, replacing the previous direct-Pymodbus path.
  • External humidity forwarding and external storage-temperature forwarding (GLT), alongside the existing per-heating-circuit room-temperature forwarding.
  • Transport diagnostics (modbus-connection/tmodbus versions, socket ownership, connection status).

Changed

  • idm-heatpump-api[web] pinned 0.9.1 → 1.0.1 (the stable API 1.x line introduces the public transport-injection contract this integration's tmodbus path relies on).
  • Minimum Home Assistant version raised to 2026.8.1; via_device → via_device_id device-registry migration.

Fixed

  • Eight confirmed bugs found in a full codebase audit (climate preset-mode safety, a write_register KeyError, a diagnostics IP-leak, a register- cache collision, a write-filter gap, reconfigure input loss, a stale device-info cache, and a zone-room validation counter reset), plus repair-issue IDs now scoped per config entry and narrower exception handling in the polling coordinator.

Known limitation

  • A Navigator 2.0/Terra SWM model-detection follow-up (#192) remains open and is being investigated post-release.

v0.11.0-beta.3 - 2026-08-05

  • Continues the direct modbus-connection==4.0.0a3 / tmodbus==0.5.0 socket with the stable idm-heatpump-api[web]==1.0.0.
  • Transient Modbus exception codes 5 (Acknowledge), 6 (Server Device Busy), 10 (Gateway Path Unavailable) and 11 (Gateway Target Failed to Respond) are now translated to ModbusException, so the API retry loop repeats them in place on the same connection instead of forcing a hard reconnect — matching the API 1.0 transport contract (retry-in-place path). Code 2 remains IllegalAddressError for the coordinator bisect logic.
  • Removed the dead _NON_RETRYABLE_DEVICE_EXCEPTION_CODES set and corrected comments that misdescribed the API retry behavior.

v0.11.0-beta.1 — 2026-08-04

  • This is the first IDM integration beta whose direct Modbus TCP socket runs through modbus-connection==4.0.0a3 with the separately pinned tmodbus==0.5.0 backend. 4.0.0a3 is the transport library version; the IDM integration version is 0.11.0-beta.1 (latest stable: 0.10.1).
  • idm-heatpump-api[web]==0.9.1 continues to own the register model, batching, encoding/decoding, model detection and write safety. Its pymodbus>=3.12.1,<4.0 dependency remains temporarily pinned because API 0.9.1 still imports it, but pymodbus no longer owns the direct socket.
  • Diagnostics and the API-version sensor now include modbus-connection and tmodbus versions plus redacted transport capabilities.
  • The adapter is implemented and covered by automated tests. Each config entry still owns its socket and reports supports_shared_connection: false because Home Assistant central cross-entry sharing is not available; read-only validation of the new path on real Navigator hardware remains pending.
  • Transient Modbus responses 5 (Acknowledge), 6 (Server Device Busy), 10 (Gateway Path Unavailable), and 11 (Gateway Target Failed to Respond) escape the batch layer without individual-read fallback or permanent register quarantine. Backend-owned busy retries are not duplicated by the adapter.
  • This beta does not satisfy the stable hardware-smoke and soak gates yet.

v0.8.5 — 2026-07-23

First stable release of the 0.8.5 line. Consolidates the eight beta candidates plus the final i18n and stability fixes from the stable code review.

Added

  • Manual Navigator model override (Auto / Navigator 10 / Navigator 2.0 / Navigator Pro), wenn die automatische Erkennung mehrdeutig ist.
  • Restart-sicherer Warmwasser-Boost mit den Services idm_heatpump.start_dhw_boost und idm_heatpump.cancel_dhw_boost sowie Start-/Cancel-Buttons. Der Boost-Zustand überlebt HA-Neustarts.
  • Optionale Gerät-Hierarchie (Wärmepumpe, DHW-Controller, Zonenmodule als separate Sub-Geräte).
  • Entity-bewusstes Modbus-Polling, Momentan-COP-Sensor und Betriebszyklus-Analyse (Verdichter-/Abtau-Zähler).
  • Navigator-Web-Binary-Sensoren für Online-/Regler-Online-Status.

Changed

  • API-Pin aktualisiert: idm-heatpump-api[web]==0.8.4 (war 0.8.1). Bringt sentinel-aware Heizkreis-Modus-Probes, robusteren Navigator-10-vs-2.0-Differenzierer für Terra SWM, automatische Kaskadenerkennung und Navigator-10-Heizkreisdaten für die Kreise B–G.
  • Klima- und Warmwasser-Entitäten melden ihre unterstützte Schrittweite (0,5 °C bzw. 1 °C für integer-backed Register).
  • Modbus-Register-Wiki gegen API 0.8.4 regeneriert.
  • Repository aufgeräumt (.planning/, alte ROADMAP.md, verwaiste Skripte und AI-Handoff-Doku entfernt).
  • README und HA-Core-Entwurf listen jetzt alle 8 Plattformen und das vollständige Service-Set inkl. DHW-Boost.

Fixed

  • Integer-Modbus-Numbers bieten keine invaliden Nachkommastellen mehr an (#158).
  • Terra SWM / Navigator 2.0 wurde fälschlich als Navigator 10 erkannt (Issue #44); die Erkennung verlangt jetzt plausible Power-Limit-Werte.
  • Water-Heater-Entität ignoriert jetzt den Unused-Sentinel und zeigt nicht mehr -1 °C als Live-Temperatur an.
  • DHW-Boost nutzt Übersetzungsschlüssel statt harter deutscher Strings; die Multi-Device-Service-ValidationError verwendet den bestehenden Schlüssel multiple_entries_select_entry.
  • DHW-Boost:DhwBoostError wird im Timeout-/Target-Restore-Pfad sauber abgefangen statt als unhandled Task-Exception durchzuschlagen.

Known limitation

  • Home Assistants experimentelle modbus_connection wird noch nicht verwendet. Der vorbereitete Transport-Vertrag bleibt bewusst inaktiv, bis die offizielle HA-Schnittstelle final ist.

v0.8.5-beta.8 — 2026-07-23

Changed

  • Neue Beta-Kandidatenversion 0.8.5-beta.8: Aktualisiert Manifest, Release-Evidence, Changelog und Wiki-Verweise auf den aktuellen Beta-Stand. Laufzeitcode, Entitäten, Register, Schreibpfade und der getestete idm-heatpump-api[web]==0.8.4-Pin bleiben unverändert.

v0.8.5-beta.7 — 2026-07-22

Fixed

  • Endgültiges Navigator-Modell wird mit der API synchronisiert: Manuelle Modell-Overrides und eindeutige spätere Web-Korrekturen gelten nun auch für die modellabhängigen Register- und Schreibprüfungen der API.
  • Zukünftiger Modbus-Transportvertrag korrigiert: Der weiterhin inaktive Vertrag unterscheidet FC04/Input Register und FC03/Holding Register und begrenzt Slave-IDs auf 1–247. Der produktive Transport bleibt unverändert.

v0.8.5-beta.6 — 2026-07-22

Fixed

  • Ganzzahlige Modbus-Werte verwenden jetzt Schrittweite 1: Heiz- und Kühlgrenzen der Heizkreise A–G sowie alle weiteren schreibbaren Integer- Register bieten keine ungültigen 0,5-Schritte mehr an.
  • Climate und Warmwasser melden die unterstützte Zielwert-Schrittweite: Heizkreis- und Raum-Sollwerte verwenden 0,5 °C, der ganzzahlige Warmwasser- Sollwert 1 °C.

v0.8.5-beta.5 — 2026-07-22

Changed

  • Pin auf idm-heatpump-api[web]==0.8.4: Aktualisiert die API-Bibliothek auf v0.8.4 für verbesserte Modbus-Modellerkennung (Erkennung aktiver Heizkreise über Betriebsmodus-Register, verlässliche Abfrage für Navigator 10 vs. 2.0 bei Terra SWM Firmware und Kaskaden-Erkennung).

v0.8.4 — 2026-07-19

Changed

  • Zonenmodul-Raumrelais ist jetzt ein binary_sensor: Der Relaisstatus pro Raum (zm{z}_room{r}_relay) wurde bisher als numerischer Sensor mit 0/1 angezeigt. Er läuft jetzt auf der binary_sensor-Plattform und zeigt on/off (Device Class Running, Toggle-Icon). Erfordert das mitgelieferte idm-heatpump-api[web]==0.8.1, in dem das Relay-Register als binary=True markiert ist. Schließt #128.
  • Pin auf idm-heatpump-api[web]==0.8.1.

v0.8.3 — 2026-07-16

Changed

  • Pin auf idm-heatpump-api[web]==0.8.0: Wirkt zwei Verbesserungen der Bibliothek automatisch aus (keine Code-Änderung an der Integration):
    • detect_model erkennt nicht-kontinuierliche Heizkreise (z. B. nur HK A und HK D installiert) zusätzlich über die Active-Mode-Register 1498–1504.
    • Der Navigator-10-Web-Client liefert Vorlauf, Pumpe und Mischer der Heizkreise B–G (vorher nur HK A und HK C).
    • Enthält den IPv4/IPv6-Web-Anmeldungsfix für den Navigator 2.0 aus API 0.7.7.

v0.8.2 — 2026-07-12

⚠️ Wichtige Hinweise zum Update (Breaking Changes)

Das direkte Update von v0.8.1 auf v0.8.2 enthält keine zusätzlichen Breaking Changes. Bei einem Update von v0.7.4 oder älter gelten weiterhin die v0.8-Änderungen: lokaler Webzugriff mit PIN, die fest gepinnte API 0.7.6, neue climate- und water_heater-Plattformen, die entfernte Entität ext_demand_brine_pump_m16, fehlertolerantes Polling und IP-unabhängige Unique IDs. Die vollständigen Hinweise stehen im Changelog.

Korrekturen

  • Benennt native Regler eindeutig als Heizkreis A, Zone 1 Raum 1 und Warmwasser, statt den Gerätenamen für mehrere Entitäten anzuzeigen.
  • Zeigt für Warmwasser den passenden Modus Wärmepumpe statt des irreführenden Status Hochleistung.
  • Vervollständigt die kanonischen Entity-Texte und sichert das Naming mit Tests ab.

v0.8.1-beta.29 — 2026-07-11

  • Remembers the successful Navigator 2.0 or Navigator 10/Pro local web protocol and retries only that protocol during normal runtime recovery.
  • Tries both supported web protocols during setup, reconfiguration and repair, and treats local network code 0 as disabled.
  • Redacts web host, web PIN and detailed web connection strings from downloaded diagnostics.
  • Adds GLT Monitor diagnosis, writable-control guidance, exact PV/battery datatypes and guarded examples for PV surplus and external DHW requests.
  • Keeps idm-heatpump-api[web]==0.7.6; this release needs a new integration version, not a new API package.
  • Consolidates verified constraints and remaining verification work in the project knowledge base and Wiki.

v0.8.1-beta.28 — 2026-07-11

  • Pins the published idm-heatpump-api 0.7.6 stability release.
  • Propagates transport failures without disabling valid registers.
  • Quarantines proven room-mode batch mismatches and avoids later double reads.
  • Recognizes the verified cascade-unavailable sentinel.
  • Restores explicitly acknowledged custom-register writes with numeric validation.

Unreleased stability audit — 2026-07-10

  • Transport/no-response failures no longer count as permanent failures of individual registers.
  • Zone-room mode validation isolates unsupported/invalid values and avoids repeated double reads after quarantine.
  • Navigator 10 cascade capability recognizes the hardware-confirmed 255 unavailable sentinel.
  • Advanced raw writes retain numeric/datatype validation and require explicit risk acknowledgement.
  • Added measurable stable-release gates.

v0.8.1-beta.27 — 2026-07-10

  • Pinned the hardware-verified API 0.7.5.
  • Added register-specific unavailable-sentinel handling.
  • Compared 170 definitions across 45 groups in 309 read-only batch/individual checks without a raw mismatch.

Historical summary

v0.4.6 — 2026-05-31

  • 169+ entities (109 sensors, 8 binary, 44 numbers, 4 selects, 4 switches)
  • Full idm-heatpump library integration (Option B complete)
  • Binary sensors for compressors, fault alarms, heating/cooling/DHW demand
  • Solar, ISC, PV, cascade registers all included
  • German entity names throughout
  • Write-only register protection (error_acknowledge)

v0.4.4 — 2026-05-31

  • Full migration to idm-heatpump library as core
  • Navigator 10 support: heat sink sensors, flow rate, groundwater temps
  • Booster A/B diagnostics (16 new sensors)

v0.4.0 — 2026-05-30

  • Major architectural change
  • Navigator 10 support added
  • First large library-backed dynamic register map

v0.2.0 — 2026-03-22

  • Initial release
  • Basic Modbus TCP integration
  • System sensors, heating circuits, DHW control