IDM Heatpump Documentation
GitHub
Edit on GitHub

Supported Devices

Compatibility Status

The detailed model and firmware status is maintained in the Compatibility Matrix. The table below is a short installation-oriented summary.

Supported Device Families

Device Firmware Heating Circuits Zone Modules Status
IDM Navigator 10 NAV10_20.23 observed on tested hardware up to 7 (A–G) up to 10 (6 default, 8 configurable) Confirmed on one maintainer test system; firmware value is evidence, not a universal minimum
IDM Navigator 2.0 2.x observed/expected up to 7 (A–G) not confirmed Expected; Navigator-10-only registers are filtered
IDM Navigator Pro unknown up to 7 (A–G) up to 10 (up to 8 configurable rooms) Expected; needs complete diagnostics report
IDM Navigator 1.7 n1.x firmware static A–G sensor slots none Read-only sensor map from the official 1.x table; PV-supplement writes when the firmware provides them; needs community testing

Requirements

  • Modbus TCP must be enabled in the Navigator controller
    • Setting: Technician level → Communication → Modbus TCP
    • Default port: 502
    • Default Slave ID: 1

Unsupported Devices

Device Reason
IDM Navigator 1.0 Separate 1.x protocol family; only the 1.7 map is implemented
IDM devices without network connection No Modbus TCP
Other heat pump manufacturers Different Modbus protocol / register layout

Untested Devices (possibly compatible)

The following devices may use the same register mapping as the Navigator 2.0 / 10, but are not yet confirmed in the public community test matrix:

  • IDM Terra SW (with Navigator 2.0 / 10 controller)
  • IDM Terra HT (with Navigator 2.0 / 10 controller)
  • IDM Aero SLM (with Navigator 2.0 / 10 controller)

Note: If you successfully use an unlisted IDM device, please share a detailed compatibility report in Q&A so we can expand the list. Select Devices or firmware compatibility in the form.

Modbus Register Compatibility

The integration builds a model- and configuration-dependent Modbus register map from the idm-heatpump library:

  • Read memory (Input Registers): Temperatures, status, energy, power
  • Read/Write memory (Holding Registers): Operating modes, setpoints, configuration

Details on all registers: Modbus Register Wiki

Compatibility evidence and report fields: Compatibility Matrix

Known Firmware-specific Differences

  • Register 1048 (current_energy_price) is optional and firmware-dependent; the integration isolates it when the active controller does not support it.
  • Zone registers (from 2000) require installed and detected/configured zone modules. They are not enabled solely from the Navigator family name.
  • PV registers (74–86) require the optional PV module

Local Web Compatibility

  • Navigator 2.0 uses the local HTTP/CSRF client (nav20 internally).
  • Navigator 10 and Navigator Pro use the Navigator-10 WebSocket client (nav10 internally).
  • Setup/reconfiguration can test both variants; normal polling remains on the one that actually succeeded. See Local Navigator Web Interface.