Protocol Capabilities

This page answers one question at a glance: what can each connection path read and write, on which Navigator family? The integration supports three paths — Modbus TCP, the local Navigator 2.0 web interface (HTTP/CSRF) and the Navigator 10/Pro WebSocket — and they complement each other. Deep background lives on Navigator Protocol Analysis, registers on Modbus Registers, hardware on Compatibility Matrix.

The three paths

Path Port Authentication Families Role
Modbus TCP 502 (unit 1) none 1.0/1.7 · 2.0 · 10/Pro The spine: full register telemetry, all validated writes
Web, old generation (PHP, no CSRF) 80 local network code, plain login session 2.0 (older firmware) Read-only supplement
Web, newer generation (PHP + CSRF) 80 local network code + CSRF token 2.0 (newer firmware) Read-only supplement
WebSocket 61220 local PIN (SYSLPIN) 10 / Pro First-class second path: values Modbus lacks + validated writes

The connection mode option decides which paths an entry uses: auto (recommended — Modbus + web supplement), modbus_web (both pinned on, no web-only fallback), web_only (no Modbus at all), modbus_only (the web interface is never contacted). See Configuration.

Controllers and interfaces: supported or not, and why

Controller / interface Status Why
Navigator 2.0 · 10 · Pro ✅ Implemented; hardware evidence varies Register map over Modbus TCP plus the web paths of this page — the combination covers the whole capability matrix below.
Navigator 1.0 · 1.7 ✅ Implemented (Modbus only; model/firmware validation varies) Official coil map and RW holding block over Modbus TCP. These controllers have no web interface of their own; the web supplement stays off for them.
Navigator 1.7 with a retrofitted 2.0 web module ⚠️ Connects; values depend on the module A 2.0-generation web module answers the nav20 client even on a 1.7 (#577): login succeeds, but the data pages may carry labels the parser does not map — most _web entities then stay unavailable while Modbus runs unaffected.
Multitalent / Multitalent.002 (older Terra and EVR series) ❌ Not supported These controllers expose no Modbus TCP. They speak a proprietary serial protocol on RS422, reachable only through an Ethernet→RS422 converter wired to the 4-pin port of the control display. Supporting them would mean implementing and validating a complete second protocol stack against field hardware — nothing of the validated Modbus and web pipelines below would carry over. Working reference: the ioBroker adapter zloe/ioBroker.idm-multitalent_002, published with IDM's consent; it runs alongside Home Assistant.
myIDM cloud portal ❌ Deliberately not used The integration is 100 % local by design; the cloud is IDM's own channel and a dependency this project does not take. Verified reference findings for future research: Navigator Protocol Analysis.
BACnet IP (UDP 47808) ❌ Not supported The Navigator offers BACnet IP as an alternative building-automation path for PV/GLT values. This integration speaks Modbus TCP on port 502 for everything and ships no BACnet stack; a BACnet installation should use a dedicated BACnet integration or gateway instead.
KNX ↗ Bridged, never implemented here The 654 IDM communication objects are served through Home Assistant's knx integration (knx.send / knx.event_register). Tunnelling, routing and KNX Secure belong to that integration — building a KNX stack here is explicitly out of scope.

Nothing marked ❌ is on a roadmap: each would need its own protocol stack (RS422 serial, cloud authentication) that cannot reuse anything this integration has validated. Where a local path exists but is undocumented, the rule from Navigator Protocol Analysis applies: no guessed writes.

Capability matrix

Legend: R readable · W writable · R/W both · — not available on that path · (note) qualifications. Unmarked cells follow the legend of their row; where a capability is firmware-dependent it says so.

Capability 1.0/1.7 Modbus 2.0 Modbus 2.0 Web (old / CSRF) 10/Pro Modbus 10/Pro WebSocket
Model & firmware detection R R R (supplement hint) R R
Core telemetry (temperatures, statuses, pumps, valves) R (1.x map) R R R R (64 values, setting pages)
Electrical / thermal power (COP inputs) — partly (not confirmed) — R — (firmware delivers neither)
Energy counters (lifetime kWh) — R (where present) — R R (heat quantities, total + today)
Statistics pages (runtime, heat, electrical) — — R (statistics.php; total values as sensors) — R (statistic blocks)
Controller clock setting (set_controller_clock service) — — W — W
Demand reason incl. PV (display wording) — — — — R (home/detail)
Message texts (info system) error codes only error codes only — error codes only R (notification, with texts)
Hot-gas, flow, board, pressures — partly partly partly R
DHW circulation / statusInfo — — — — R (system.freshwater)
Controller clock / jsonVersion / userlevel — — — — R (status/overview)
Operating mode (system) R/W (holding block) R/W — R/W R/W (home/save)
DHW setpoint R/W (2152) R/W — R/W R/W (FW030, device-range-validated)
Heating-circuit mode R/W (holding block) R/W — R/W R/W (HK<x>01)
Room setpoint (normal) R/W (holding block) R/W — R/W R/W (HK<x>04, device-range-validated)
Heating curve / limits / shift R/W (holding block) R/W — R/W W possible (parameter ids known, not yet mapped)
Error acknowledge W (coil c3000, FC05) W (register 1999) — W (register 1999) W (notification/save)
DHW one-shot boost W (demand coil c3003) W (boost state machine) — W (boost state machine) — (weekly timetable only, no one-shot command)
GLT inputs (ext. room temp, humidity, PV surplus) W (PV supplement 74–88) W — W — (level-0 GLT container answers empty)
Zone-module rooms — (separate family) R/W (registers) — R/W R/W (room controller; not yet mapped)
KNX bridge serve (shared names only) serve + commands — serve + commands serve + commands (everyday controls via WS)
COP / energy statistics — partly — yes no (needs the power inputs)

What this means in practice

  • Full operation (recommended auto): Modbus delivers everything, including the power values behind COP and energy statistics; the web supplement adds the values Modbus never had (demand reason, message texts, hot-gas, circulation, device-side statistics).
  • web_only (Navigator 10/Pro): a genuine operating mode — 10-second polls, climate/water-heater cards, KNX serving and the validated writes of the matrix above. What it cannot replace: COP/energy statistics (power values), GLT forwarding and the one-shot DHW boost — those need Modbus.
  • Navigator 2.0: Modbus carries the load; the CSRF web interface is a read-only supplement (its write semantics were never captured and validated — deliberately not offered).
  • Navigator 1.0/1.7: Modbus only, including the official RW holding block and the coil commands. No web module exists; the local web supplement should stay disabled. Holding-block writes are EEPROM-limited — the integration guards them with cooldowns and EEPROM intervals.

Write safety on every path

Guard Modbus WebSocket
Range/enum validation before sending API register metadata device's own declared min/max (read before write)
EEPROM protection EEPROM-sensitive list + 60 s interval per register (EEPROM load not documented for web writes; pacing applies)
Confirmation read-back through the register poll <controller>Save success note required; rejection raises
Transient-zero guard lifetime counters lifetime counters (same snapshot)

Writes use defined, validated operations. W identifies an implemented write path, not complete hardware confirmation across all models and firmware. Automated tests, protocol captures, Modbus acknowledgements and physical results are separate evidence levels. See Compatibility Matrix for model-specific confirmation. Cells marked (not yet mapped) are not supported entity features.