Findings and documentation

This is the entry point for field discoveries and the documentation review process. The wiki follows the source tree shown on Home; an installed release uses its tagged manifest. Release history stays in Changelog.

Findings register

Finding Evidence and scope Practical consequence and open questions
Issue #577 capture replay Two issue-referenced private captures passed archive-ledger verification and were replayed with API 2.16.1. HTTP JSON yielded three circuit flow temperatures; the checked WebSocket status/home responses parsed and its HTTP data paths were 404s. Capture notes do not prove controller identity or attribution to the original module. Missing quantities are not inferred. Compare current reporter diagnostics, API version and parsed keys with the exact module before claiming a parser fix.
External-power GLT entity recovery (#493) Regression reproduces a read-only sensor omitted when startup reads an unset sentinel; supported inputs now retain their entity and recover on valid readback. See Configuration. Writable Numbers already retain sentinel availability and polling dependencies. This correction does not itself fix controller-side battery display flicker; absent/unsupported registers remain filtered.
Battery use requires register 84 (#493) IDM support confirmed to the #493 reporter that when a battery is used, register 84 (battery_discharge) must be written. After mapping battery charge/discharge together with SoC, the reporter saw no further flicker. See external power setup. Map battery charge/discharge as well as SoC. For two batteries, forward the sum of their signed power (positive = discharge). This is a controller input requirement, not an integration defect. IDM did not confirm that every other external-power register must be written in every cycle.
PV message 20300 at valid zero production A controlled series on a Navigator 10 (2026-11-10) established the mechanism: the message latches when the forwarded pv_production register stays unchanged for about ten minutes — regardless of its level — and any value change clears it within seconds. There is no wattage threshold; the workaround alternates 10/20 W every minute. Tested firmware and procedure in Configuration. Alternating 10/20 W heartbeat workaround; affects controller PV displays/statistics. Does not prove every 20300 warning has this cause or fix communication failures.
NAV10_ and T_NAV10_ firmware prefixes Controller-family matching accepts both exact prefixes; lookalikes such as NAV100_ are rejected. See Configuration. HTTP transport alone does not identify a Navigator 2.0. Explicit model overrides retain precedence.
Shared Modbus connections The active provider reports shared ownership when Home Assistant's unit API can be claimed; failures use the private transport. See Troubleshooting. Read actual source, owns_socket and supports_shared_connection diagnostics before investigating duplicate clients. A successful TCP connection alone does not prove correct register data.
Heat-sink flow is FLOAT32 Field readings exposed an outdated UCHAR declaration in older register tables. See Known limitations. Missing plate-heat-exchanger values may correctly be unavailable; avoid interpreting a decode artifact as zero physical flow.
Differential circuits have different semantics Existing register readings represent storage/reference temperatures and signed reference-minus-storage difference. See Configuration and Entities. Keep the normal circuit selection as well as the differential selection. Threshold/hysteresis mapping and full hardware confirmation remain open; equal displayed values are not proof of register meaning.
Firmware observations are not update offers The optional catalog matches community observations to controller/model/software metadata. See Telemetry. Independent opt-in, no installation, no guaranteed plant-specific availability. Only iDM or an authorized installer can assess an update.
Observed optimization needs comparable history Reports, Predictive Advisor and Assist share bounded evidence. See Predictive Advisor. Requires before/after history and suitable coverage. Weather and use can differ; an association does not establish causality or savings.
Web-only has model-specific controls Navigator 10/Pro offers selected validated controls; Navigator 2.0 HTTP remains mainly a read-only supplement with a clock action. See Protocol capabilities. GLT forwarding, one-shot DHW boost and calculated COP power inputs still need Modbus. A protocol feature is not automatically an implemented entity.
Installer access belongs to the installer Installer-code entities were removed; see Known limitations and Installer checklist. The integration does not calculate access codes or install firmware.
B10 high-pressure contact is closed when healthy The web binary-sensor definition inverts B10 like B5/B15; the correction is recorded in Changelog. Closed means no fault, open means fault. Incorrect polarity can mimic a permanent fault; check real faults on the controller.
Telemetry counters must match their observation window Independent analysis stores can be newer than the telemetry checkpoint after reload. See data and delivery. Recovery uses a coherent time/counter pair. Older checkpoints omit operating durations once in a transitional report; HA operating and energy history is preserved.
Navigator 1.x supports more than reads The official 1.x map includes a writable holding block and momentary coil actions. FHEM capture evidence and API contract tests are scoped in Compatibility Matrix. Implemented support does not establish complete physical validation for every model/firmware combination. Respect EEPROM limits and never automate priority charging cyclically.
Unwired temperature inputs answer with memory garbage A Navigator 2.0 heating circuit without an iDM room sensor reports about -327 °C on register 1364 (observed -327.33 and -327.22; issues #504, #668) instead of a declared sentinel. The value is finite and stable per boot. The integration treats readings at or below -300 °C on temperature registers as "sensor not present": the health check ignores them, the sensor entity becomes unavailable (unless raw values are requested) and climate/water-heater cards publish no temperature. High-side garbage has no field evidence and remains flagged.
Hot water station flow reads the potable side The web flowmeter row (web_hotwater_station_flowmeter, controller sensor B108) follows the tap, not a fixed-speed charging circuit: 48 h of recorder history on a Navigator 10 ALM (firmware 20.24-1580, integration 0.27.0-b4, 2026-11) recorded 108 tapping events spanning 0.5–19.4 L/min. Typical shower draws clustered at 5.5–6.1 L/min (about 80 % of active samples), a wide-open bath tap peaked at 19.4 L/min, idle reads 0.0. See Entities. A near-constant ~6 L/min display is a typical shower draw, not a stuck sensor. Station names such as "35 l" are tapping-capacity ratings (35 L/min), not measured flow. Heating-side flow remains the separate B2 / register 1072 entity. The physical line B108 sits on is inferred from behaviour; no IDM document states it.

Recording the next discovery

Record the controller family, relevant firmware, integration/API versions, connection mode and the exact observation. Remove credentials, PINs, addresses, myIDM IDs and unrelated personal data before publishing. Link a redacted issue, capture description or reproducible test where available.

State separately what was observed, what the implementation guarantees, what is inferred and what still needs confirmation. A successful write or HTTP acknowledgement does not establish physical behavior or long-term reliability. Publish the explanation on the relevant feature page and its German mirror, then add a concise entry here. Protocol details belong in Navigator Protocol Analysis, cross-model evidence in Compatibility Matrix, and unresolved restrictions in Known limitations.

Keeping the wiki current

Every integration source module is assigned to user documentation in docs/wiki-coverage.json. A source fingerprint records the tree that was reviewed for each feature group. A changed module, new module, missing mirror, unpublished page or undocumented service causes the documentation coverage check to fail. The check also rejects obsolete release announcements on Home.

After reviewing the relevant English and German pages against a code change, run python scripts/check_wiki_coverage.py --update to acknowledge the reviewed source fingerprints. Inspect the resulting diff: this command updates the review record, not the prose. Never use it as a substitute for documentation review. New functionality needs setup, defaults, controls, privacy implications, failure behavior and limitations on its feature page.

CI, dependency validation, release validation and Pages deployment enforce the coverage check as well as version consistency. Automated checks make omissions visible; they cannot prove that every sentence is correct. Recheck field claims when new evidence contradicts them. Do not rewrite published release history to match current behavior.

Donation review: 9 November 2026

Three additional diagnostic ZIPs and six additional telemetry reports were reviewed. The two Navigator 10 ZIPs contain usable web and statistic responses; numeric setting parameters parse with the parameter reader and must not be routed to the HTML-section parser. A note-only reply explicitly stating that a circuit is unavailable is separate from malformed JSON. API 2.16.2 and integration 0.26.11 retain other successful circuits; diagnostics list absent circuit letters without copying names or controller response text.

Open work, not forgotten or declared fixed:

  • The donation declared as NAVIGATOR Pro has 499 readable FC03/FC04 words, including 48 function/address pairs absent from earlier readable references. Attribution, scaling and physical model remain unverified: do not create entities or change official register definitions from readability alone.
  • Its HTTP login remains at an authentication form; the cause is not proven to be an incorrect PIN. Compare a fresh browser login and the capture tool's sanitized per-attempt trace before changing an authentication flow.
  • Physical heat-pump models are absent in all eight reviewed telemetry reports. Capability flags are API model metadata, not proof of installed equipment.
  • Five later telemetry reports have coherent complete duration counters; the transitional report intentionally omits them. Historical inconsistencies stay flagged. Do not mix stable NAV10_ and test-channel T_NAV10_ observations.
  • #577's remaining parser and packed-register questions need exact issue-linked evidence. #649 has a healthy-state field confirmation; a forced fault was not tested. #493 is answered: IDM support requires register 84 to be written when a battery is used. #668 still awaits reporter confirmation. Existing public replies remain separate from a verified general controller requirement, except for this IDM confirmation of register 84.

The private originals stay under their existing retention policies. Synthetic regression fixtures reproduce structures only; no donated readings or private notes are published. A reviewed inbox status means the evidence was evaluated, not that every open hypothesis is fixed or every address has a mapping.

Donation review: 10 November 2026

Fresh Navigator 10 capture replays with API 2.16.2 confirm that explicitly unavailable heating circuits and freshwater components remain missing rather than becoming fabricated zeroes. Weather forecasts and numeric parameters parse successfully. Different menu counts reflect reported availability; identical firmware and Modbus address coverage do not establish one physical plant.

The server now exposes affected-report counts and web-outage coverage alongside paired Modbus failure ratios, both overall and by comparison cohort. A small overall ratio must not hide an affected report. These are reported communication observations, without a proven cause or outage duration; otherwise coherent runtime/energy observations are not discarded automatically. No extra client data, consent change or controller request is introduced. See telemetry review quality.

A menu type set narrowing from number-or-text to text-only is visible in the private structure diff but adds no new type fact for the selective notification. Synthetic regressions cover the distinction and preserve notification for a genuinely unseen type. No new API parser change is justified by this difference. Physical heat-pump model metadata, ambiguous Pro component attribution and explicit observation boundaries remain open; firmware matching continues to use source metadata rather than a hardcoded latest version.

Code copied