Installer Checklist

Everything the integration needs for full operation is enabled at the controller's installer level by your heating installer — the integration itself never unlocks anything and needs no access code. Print this page (browser print dialog, Destination → Save as PDF) and hand it to your installer; every item can be ticked off in a few minutes on site.

Printable translations of this checklist: Español · Italiano · Română · Čeština · Polski

1. Network

☐ Item Notes / value
☐ Fixed IP address for the Navigator (DHCP reservation in the router or static on the controller) IP: ______________________
☐ Navigator and Home Assistant reach each other in the same local network
☐ No port forwarding or internet exposure for ports 502, 80 and 61220 — everything stays local

2. Modbus — required, the backbone

☐ Item Notes / value
☐ Building management system (Gebäudeleittechnik) → Modbus TCP → On / Ein
☐ TCP port left at the default normally 502
☐ Slave/unit ID normally 1
☐ Controller clock shows the correct local date and time

3. PV / GLT — optional: PV surplus, battery, external room sensors

☐ Item Notes
☐ PV signal source set to Building management / Smartfox (no native inverter polling by the controller)
☐ GLT input registers released (74–86: surplus, PV production, house consumption, battery power, battery SOC)
☐ No other energy manager writes to the same GLT registers

4. Local web interface — optional: web-only fallback and extra values

☐ Item Notes / value
☐ Network/web PIN set on the controller and handed over to you PIN: ______________________
☐ Web interface reachable in the local network (HTTP port 80; Navigator 10 additionally WebSocket port 61220)

5. Plant information for the setup — the installer reads these off

Item Value
Navigator generation (1.0 / 1.7 / 2.0 / Pro / 10) ______________________
Software/firmware version (service menu or web page) ______________________
System scheme number (Anlagenschema, e.g. L7.1) ______________________
Active heating circuits (A–G) ______________________
Zone modules and rooms per module ______________________
Cascade present? Number of units ______________________
Solar thermal / ISC module present? ______________________

What the integration does not need

  • No cloud access and no myIDM account — control stays 100 % local
  • No port forwarding, no DMZ, no external access of any kind
  • No unlocking of installer menus during operation

Once your installer has confirmed the items above, continue with Installation and Setup.